DSpace Repository

le concept de la zone neutre en prothèse Amovible complète Étude comparative de l’espace prothétique enregistré par la technique de zone neutre et la Technique piézographique

Show simple item record

dc.contributor.author Aloui, Imane
dc.contributor.author Matmat, Yasmine Rihanna
dc.contributor.author Boulaiche, Rania
dc.contributor.author Meriche, Fela Anissa
dc.contributor.author Kias, Wissal
dc.contributor.author Messai, Amani
dc.contributor.author Kouadria, Hadjer
dc.contributor.author Yakhlef, Ghada
dc.contributor.author Dr. HAMIZI, Abdesselam
dc.date.accessioned 2023-02-08T10:37:11Z
dc.date.available 2023-02-08T10:37:11Z
dc.date.issued 2022
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/220
dc.description.abstract La conception d'une prothèse parfaitement stable nécessite l'exploitation maximale du potentiel rétentif de la musculature orofaciale. Deux techniques ont été développées à partir de l'enregistrement de ces surfaces polies : la piézographie et le concept de la zone neutre, qui visent à reproduire en trois dimensions l'espace prothétique enregistré. Dans ce travail, à travers une étude expérimentale, on essayera d’évaluer et comparer les enregistrements de l’espace prothétique avec la technique du concept de zone neutre et la technique piézographique chez un patient édenté totalement. L’objectif de ce travail est de : - évaluer et comparer l’espace prothétique et la forme des surfaces polies enregistrés par la technique de concept de zone neutre et la piézographie. L’analyse des deux enregistrements est réalisée avec la technologie CFAO à met en évidence une certaine différence au niveau postérieur sur le plan du volume et de la forme. Une épaisseur plus importante lingualement pour la zone neutre et des surfaces plus inclinés pour la piézographie. Abstract:The design of a perfectly stable prosthesis requires the maximum exploitation of the retentive potential of the orofacial musculature. Two techniques have been developed based on the recording of these polished surfaces: piezography and the neutral zone concept, which aim to reproduce the recorded prosthetic space in three dimensions. In this work, through an experimental study, we will try to evaluate and compare the recordings of the prosthetic space with the neutral zone concept technique and the piezographic technique in a totally edentulous patient. The objective of this work is to: - Evaluate and compare the prosthetic space and the shape of the polished surfaces recorded by the neutral zone concept technique and piezography. The analysis of the two recordings is carried out with CAD/CAM technology to highlight a certain difference at the posterior level in terms of volume and shape. A greater thickness lingually for the neutral zone and more inclined surfaces for piezography. en_US
dc.language.iso fr en_US
dc.publisher Université Salah Boubnider 3, Faculté de médecine en_US
dc.subject prothèse amovible complète en_US
dc.subject la piézographie en_US
dc.subject le concept de zone neutre en_US
dc.subject l’espace prothétique en_US
dc.subject les surfaces polies stabilisatrices en_US
dc.title le concept de la zone neutre en prothèse Amovible complète Étude comparative de l’espace prothétique enregistré par la technique de zone neutre et la Technique piézographique en_US
dc.type Other en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account